VP 720F-1

VP 720F-1

STIR ELEMENT, SUPER DISCS, Stainless Steel, Parylene C Coated, Used in Microplates, Syringes, Tubes/Vials, 1000/pack

Add to quote

STIR ELEMENT, SUPER DISCS, Stainless Steel, Parylene C Coated, 9.6mm Diameter, 0.7mm Height, 200°C Max Operating Temp for Coating

Shape

Discs

Container Used

Microplates, Syringes, Tubes/Vials

No of Wells

24

Plate Type

Standard

Well Bottom Shape

All Shapes

Syringe Volume

5mL

Tube/Vial Volume

5mL

Diameter

9.6mm

Height

0.7mm

Magnet Type

Stainless Steel

Temp Resistant

200°C Max Operating Temp

Autoclavable

Yes

Encapsulation/Coating

Parylene C Coated

Max Element Size

8.0mm – 9.9mm

Unit of Measure

1000/pack

V&P Scientific Makes a Wide Range of Stir Elements that can be Tailored to Meet Your Needs and Applications.

Wide Variety of MATERIALS

  • Stainless Steel
  • ALNICO,
  • Samarium Cobalt and
  • Neodymium Iron Boron (NdFeB)

 

Wide Variety of COATINGS

  • PTFE
  • PTFE Sandwich style
  • Parylene
  • PEEK
  • PVDF
  • Glass Encapsulated
  • High-Temperature Resin

 

Wide Variety of STIRRING CONTAINERS

  • Micro Chambers
  • Microplate Wells
  • Test Tubes
  • Vials
  • Syringes
  • Reservoirs
  • Bottles
  • Flasks
  • Carboys
  • Barrels
  • 600 Gallon Containers

 

Wide Variety of SHAPES AND SIZES

  • Complex 3D-printed stir elements
  • Cross
  • Curve shapes
  • Disc
  • Dumbbell
  • Egg shape
  • Fan
  • Giant Stir Bars
  • Heart shapes
  • H-shapes
  • Mini and Micro Stir bars
  • Ovals
  • Paddle top
  • Paddles
  • Rectangle
  • Spheres
  • Stick
  • Stir Bars
  • Torpedoes
  • Trapezes
  • Triangles
  • Tuning forks
  • Umbrella
  • U-shaped
  • V-shapes

We have designed these stir elements to work specifically with our powerful drive NdFeB magnets USED ON OUR STIRRERS

  • Vertical Tumble Stirrers (VP 710 series)
  • Lateral Vortex Stirrers (VP 708 series)
  • Levitation Stirrers (VP 707 series)
  • Horizontal Stirrers (VP 706 series)

V&P Scientific stir elements are used in Redox Chemistry, Pharmaceutical, Biotech, and Biological research, Environmental Toxicity Assays for heavy metals, the Food Industry, Breweries, E-Cigarettes Juice, and even Marijuana processing to name a few.

Stir Element Applications

V&P Stir Elements were designed to mix and stir the contents of microplate wells and to facilitate chemical or biological reactions.   These stir elements work best when used with the strong magnetic fields generated by our Vertical Tumble Stirrers or with our Lateral Vortex Stirrers using NdFeB magnetic cylinders.  The strength of these magnetic fields is so strong that they will even cause inexpensive weakly magnetic stainless steel stir elements to tumble when they are 12.8 cm above the stirrer’s deck.  Furthermore, the cost of the stainless steel stir elements is so low as to be considered “disposable”.

High Throughput Stirring Platform

The NdFeB magnetic cylinders used with both our Vertical and Lateral Tumble Stirrers are constructed to project a very strong magnetic field for 60 cm. When used with our Vertical Tumble Stirrers, microplates can be stirred when stacked 8 microplates high (12.8cm) with stainless steel stir elements and stirred up to 19 microplates high (30.4 cm) when used with NdFeB stir elements. This great projection of magnetic field strength allows for experiments of up to 40 microplates using stainless steel stir elements and 95 microplates when using NdFeB stir elements on a VP 710E5.

Parylene Coating of Tumble Stir Element

V&P Scientific also offers inexpensive stainless steel stir elements that are coated with parylene, for those applications facilitated by mixing (combinatorial chemistry and redox synthesis) where Fe molecules may interfere with the reaction, or the stirrers would be attacked by strong acids or bases.   The low cost of these parylene-coated stir elements allows them to be considered “disposable”.   Parylene (Di-Para-Xylylene) is deposited on the surface of the stirrer in a very uniform 0.05 mm thick layer, thus protecting the stirrers from strong acids and bases.  Parylene-coated stirrers can be autoclaved or sterilized in hot air ovens without harming the conformal coating.  Parylene can be heated to 200°C without harming the surface.

Parylene is also compatible with biological applications.  In fact, parylene is used to coat materials for implant procedures, as it is completely non-toxic to tissues.  See this page for a complete discussion of parylene’s barrier characteristics, properties, and methods of deposition.  See this page dedicated to parylene’ s resistance to organic solvents, acids, and bases. The Parylene Coated Tumble Stirrers can be dispensed with the same dispensers as their non-coated counterparts.

Many of the applications using parylene-coated stainless steel stir elements fall into the categories of parallel synthesis, combinatorial chemistry, and redox synthesis that are done by pharmaceutical companies, and most are never published in order to keep their data and methods private.  One of our customers at a large pharmaceutical company sent us this compliment in an email –

Testimonial

“Patty and Patrick-

There is a long, official process (read: involves the Legal department) for allowing endorsements of products with _______’s and/or my name. However, I would be happy to share my personal feedback with you.  If you would like to refer to this to anyone as unofficial information (ie, “It came from someone in Process R&D in major Pharma.”), that would be great. At the least, you’ll see exactly why I love these stirrers.

Feedback for the Tumble Stirrers is this: enabling technology. I am now enabled to create reaction blocks and customize them to robotic systems with great ease.  Why? The narrow deck height of the Tumble stirrers (even my larger strength units) combined with the flexibility of alignment for the stirrers to the reaction vessels means I can use them almost anywhere.

The fact that I can use the same stirrer deck with any type/size of reactor simply by changing a mounting plate atop the stirrer deck gives me the kind of flexibility I require for parallel synthetic development of processes. That flexibility enables access to a wider range of projects (smaller scale) and a wider range of reaction conditions. I get more reactions per gram of starting material for evaluation of more diverse conditions, and I generate results faster because I run more of the experiments in parallel using the same amount of starting material. In one word, Tumble Stirring is enabling.

Oh, and the quality of agitation is fantastic for liquid-liquid mixes, slurries, or even oil suspensions.

Thanks again for this terrific product.

D____.”

Related Products

Hydrophobic Coated vs Non-Coated Pin Transfers

Solid Pin Delivery Data For Aqueous Solutions In 96 Format With Uncoated And /Ah Hydrophobic Coated Pins
PinDescriptionnl TransferredCV%
0.229 mm diameter (FP9)Total PinUncoated7.412.4
Hydrophobic7.465.4
0.229 mm diameter (FP9)Hanging DropUncoatedN/AN/A
Hydrophobic2.093.8
0.457 mm diameter (FP1)Total PinUncoated33.483.2
Hydrophobic28.177.5
0.457 mm diameter (FP1)Hanging DropUncoated16.964.5
Hydrophobic8.510.8
0.787 mm diameter (FP3)Total PinUncoated87.323.9
Hydrophobic77.43.9
0.787 mm diameter (FP3)Hanging DropUncoated48.771.2
Hydrophobic43.059.4
1.19 mm diameter  (VP 409 & VP 386)Total PinUncoated247.222.8
Hydrophobic192.672.6
1.19 mm diameter (VP 409 & VP 386)Hanging DropUncoated76.351.6
Hydrophobic108.42.8
1.58 mm diameter (VP 408 & VP 384)Total PinUncoated273.54.6
Hydrophobic259.253.1
1.58 mm diameter (VP 408 & VP 384)Hanging DropUncoated201.935
Hydrophobic170.047.5

Transfer Of Horseradish Peroxidase In Tris Buffered Saline With Pin Tools

Conclusion

Coating pins will reduce the total amount of liquid transferred and also reduce the amount of non-specific binding to the stainless-steel pins. If the substance you are transferring has high non-specific binding this will be an important factor in selecting your pins.

Slot Pin Delivery Data For Aqueous Solutions In 96 Format With Uncoated And /Ah Hydrophobic Coated Pin
PinDescriptionnl TransferredCV%
0.229 mm diameter (FP9)Total PinUncoated7.412.4
Hydrophobic7.465.4
0.229 mm diameter (FP9)Hanging DropUncoatedN/AN/A
Hydrophobic2.093.8
0.457 mm diameter (FP1)Total PinUncoated33.483.2
Hydrophobic28.177.5
0.457 mm diameter (FP1)Hanging DropUncoated16.964.5
Hydrophobic8.510.8
0.787 mm diameter (FP3)Total PinUncoated87.323.9
Hydrophobic77.43.9
0.787 mm diameter (FP3)Hanging DropUncoated48.771.2
Hydrophobic43.059.4
1.19 mm diameter  (VP 409 & VP 386)Total PinUncoated247.222.8
Hydrophobic192.672.6
1.19 mm diameter (VP 409 & VP 386)Hanging DropUncoated76.351.6
Hydrophobic108.42.8
1.58 mm diameter (VP 408 & VP 384)Total PinUncoated273.54.6
Hydrophobic259.253.1
1.58 mm diameter (VP 408 & VP 384)Hanging DropUncoated201.935
Hydrophobic170.047.5

Transfer Of Horseradish Peroxidase In Tris Buffered Saline With Pin Tools

Conclusion

Although the slots in the pin are a precise volume, the liquid that is transferred is usually more. The reason for this is due to the surface tension of the liquid causing the liquid in the slot to “bow out” thus increasing the volume of the liquid in the slot. If is important for you to transfer exactly a certain volume we can make custom slots to match the surface tension characteristics of your liquid

Liquid Surface Tension

Effect Of DNA Or BSA Concentration On Slot Pin Transfers Of Uncoated And Hydrophobic Coated Pins (FP3CS500)
Solvent/SampleConcentrationCV%nl FITC TransferredCV%nl FITC Transferred
UncoatedUncoatedHydrophobic CoatedHydrophobic Coated
DMSO (-)08.1353.427.5298.72
DMSO + DNA (mg/ml)0.56.6497.216.6435.86
0.259432.494.1391.93
0.1258.9363.640.9344.75
0.06252.3381.862331.68
0.03131.5378.034.4331.71
0.01561.2357.521.4329.03
Tris (-)04.9577.317.2493.53
Tris + DNA (mg/ml)0.54.5540.531.1477.5
0.254.6518.216.1456.75
0.12515.8583.254.1438.82
0.06254.2551.173.1433.69
0.03134.4536.662.3458.37
0.01562.9528.531.2441.1
Tris + BSA (%)45.4462.1311409.27
14452.862.7426.58
0.2511.7456.451.3408.72
0.06251.1445.226.5393.07
0.01563.7462.853.9430.2
0.00391.5493.542.2437.29
0.0012.9504.250.7475.96
Conclusions

1. Increasing the concentration of DNA (sheared salmon sperm) to .25 mg/ml significantly increases the volume of DMSO liquid transferred for both coated and uncoated FP3S500 Slot Pins.
2. Increasing the concentration of DNA does not significantly increase the volume of Tris buffer (aqueous) transferred by both coated and uncoated FP3S500 Slot Pins.
3. Increasing the concentration of BSA (Bovine Serum Albumin) significantly decreases the volume of Tris buffer transferred by both coated and uncoated FP3S500 Slot Pins.
4. Hydrophobic coated FP3S500 Slot Pins transferred less DMSO – DNA and less Tris DNA and less Tris BSA than the uncoated FP3S500 Slot Pins.
5. Both coated and uncoated FP3S500 pins transfer significantly more aqueous solution than DMSO.

Effect Of DNA Or BSA Concentration On Slot Pin Transfers Of Uncoated And Hydrophobic Coated Pins (FP1CS50)
Solvent/SampleConcentrationCV%nl FITC TransferredCV%nl FITC Transferred
UncoatedUncoatedHydrophobic CoatedHydrophobic Coated
DMSO (-)04.249.382.149.31
DMSO + DNA (mg/ml)0.54.951.242.656.79
0.251.750.21.249.53
0.1251.551.272.349.77
0.06252.249.344.148.19
0.03131.249.030.250.23
0.01562.445.91.446.64
Tris (-)02.689.512.991.34
Tris + DNA (mg/ml)0.5777.110.684.62
0.253.982.221.684.89
0.1253.985.42185.08
0.06251.585.362.885.03
0.0313284.52388.19
0.01562.682.922.883.2
Conclusions

1. In contrast to the FP3S500 data, increasing the concentration of DNA to .25 mg/ml does not significantly increase the volume of DMSO liquid transferred for both coated and uncoated FP1S50 Slot Pins.
2. Increasing the concentration of DNA does not significantly increase the volume of Tris buffer (aqueous) transferred by both coated and uncoated FP1S50 Slot Pins.
3. In contrast to the FP3S500 data, FP1S50 coated pins transferred about the same volume of DNA at all concentrations as did uncoated pins.
4. Both coated and uncoated FP1S50 pins transfer significantly more aqueous solution than DMSO.
5. The differences between the FP3S500 and the FP1S50 pin may be due to the different pin diameter’s effect on contact angle and therefore on the “wetting” of the pin. See the diagram on the link to / ah energy system.

PinDescriptionnl TransferredCV%
0.229 mm diameter (FP9)Total PinUncoated7.412.4
Hydrophobic7.465.4
0.229 mm diameter (FP9)Hanging DropUncoatedN/AN/A
Hydrophobic2.093.8
0.457 mm diameter (FP1)Total PinUncoated33.483.2
Hydrophobic28.177.5
0.457 mm diameter (FP1)Hanging DropUncoated16.964.5
Hydrophobic8.510.8
0.787 mm diameter (FP3)Total PinUncoated87.323.9
Hydrophobic77.43.9
0.787 mm diameter (FP3)Hanging DropUncoated48.771.2
Hydrophobic43.059.4
1.19 mm diameter  (VP 409 & VP 386)Total PinUncoated247.222.8
Hydrophobic192.672.6
1.19 mm diameter (VP 409 & VP 386)Hanging DropUncoated76.351.6
Hydrophobic108.42.8
1.58 mm diameter (VP 408 & VP 384)Total PinUncoated273.54.6
Hydrophobic259.253.1
1.58 mm diameter (VP 408 & VP 384)Hanging DropUncoated201.935
Hydrophobic170.047.5

Aqueous Transfer with Solid Pins

Hydrophobic coating pins will reduce the total amount of aqueous HRP liquid transferred and also reduce the amount of non-specific binding to the stainless-steel pins. If the substance you are transferring has high non-specific binding this will be an important factor in selecting your pins.

 

Pin diameter also has an effect on the degree of reduction of liquid transfer with hydrophobic coating as the smaller the diameter the less the reduction of transfer. This is most likely due to the curvature of the pin affecting the wetting contact angle

PinDescriptionnl TransferredCV%
0.457 mm diameter (FP1)6 nl SlotTotal Pin*Uncoated25.610.8
HydrophobicN/AN/A
10 nl SlotTotal Pin*Uncoated23.366.1
Hydrophobic25.856.9
50 nl SlotTotal Pin*Uncoated67.832.5
HydrophobicN/AN/A
0.787 mm diameter (FP3)  100 nl SlotTotal Pin*Uncoated180.327.2
Hydrophobic205.845.5
200 nl SlotTotal Pin*Uncoated277.824.9
Hydrophobic287.33.8
500 nl SlotTotal Pin*Uncoated581.165.2
Hydrophobic555.693

DMSO Transfer with Slot Pins

Hydrophobic coating pins will slightly increase the total amount of DMSO FITC liquid transferred.

PinDescriptionnl TransferredCV%
0.787 mm diameter (FP3)    100 nl Slot Total Pin, Including SlotUncoated195.691.6
Hydrophobic170.22.9
0.787 mm diameter (FP3)  100 nl Slot, Slot OnlyUncoated149.674.9
Hydrophobic129.617.6
0.787 mm diameter (FP3)200 nl Slot Total Pin, Including SlotUncoated269.771.9
Hydrophobic228.6217.1
0.787 mm diameter (FP3)200 nl Slot, Slot OnlyUncoated237.528.9
Hydrophobic186.95.9

Aqueous Transfer with Slot Pins

Although the slots in the pin are a precise volume, the liquid that is transferred is usually more because of the volume carried on the sides of the pins. 

As seen with other aqueous data the amount transferred on hydrophobic coated Slot pins is less than on uncoated Solid or Slot pins. Thus Hydrophobic coating has the most effect on aqueous transfers.

Withdrawl Speeds Impact on Volume Transfer

Solid Pins More affected by Source Plate Volume

Volume Transferred For FP1 Pins (Uncoated) In 96 And 384 Formats
Volume Transferred For FP3 Pins (Uncoated) In 96 And 384 Formats

Note: Same volume (200ul for 96 Format and 74 ul for 384 Format) in recipient plates and same pin withdrawal speed for all pins. Changes to pin withdrawal speed or volume in the source plate can result in different volumes being transferred.

Transfer volumes should always be confirmed by customers for their assay conditions and automated system.

Aqueous Solutions Pin Transfer Volumes Ranges

Aqueous Solutions on Uncoated Pins in 96 Format Microplates(1)
Pin TypePin Diameter(mm)Shape96 Format Low Range(nL)²96 Format High Range(nL)²
FP90.229Solid1339
FP80.356Solid1537
FP10.457Solid2261
FP1S60.4576nL Slot3467
FP1S100.45710nL Slot3974
FP1S500.45750nL Slot90124
FP30.787Solid93213
FP3S1000.787100nL Slot213334
FP3S2000.787200nL Slot311449
FP3S5000.787500nL Slot515671
FP40.914Solid126289
Footnotes: (1) Delivery volume range is determined by speed of withdrawal from source liquid: Z-Speed Range = 1.5-30 mm/sec, slow speed = low volume delivery range, fast speed = high volume delivery range (2) 200ul source plate volume per well
Aqueous Solutions on Hydrophobic Pins in 96 Format Microplates(1)
Pin TypePin Diameter(mm)Shape96 Format Low Range(nL)²96 Format High Range(nL)²
FP90.229Solid1338
FP80.356Solid
FP10.457Solid2360
FP1S60.4576nL Slot3367
FP1S100.45710nL Slot4075
FP1S500.45750nL Slot86119
FP30.787Solid76209
FP3S1000.787100nL Slot188324
FP3S2000.787200nL Slot288436
FP3S5000.787500nL Slot473649
FP40.914Solid
Footnotes: (1) Delivery volume range is determined by speed of withdrawal from source liquid: Z-Speed Range = 1.5-30 mm/sec, slow speed = low volume delivery range, fast speed = high volume delivery range (2) 200ul source plate volume per well
Aqueous Solution on E-Clip, Uncoated Pins(1)
Pin TypePin Diameter(mm)ShapeLow Range(nL)²High Range(nL)²
FP1.58Solid Pointed175594
FPS.51.58500nL Slot524962
FPS1.581000nL Slot10561476
FPS21.582000nL Slot17392174
FPS51.585000nL Slot51504953
FP61.58Solid Flat465960
FP6S.51.58500nL Slot9341445
FP6S1.581000nL Slot13961930
FP6S21.582000nL Slot20722637
FP6S51.585000nL Slot48204693
Footnotes:(1) Delivery volume range is determined by speed of withdrawal from source liquid: Z-Speed Range = 1.5-30 mm/sec, slow speed = low volume delivery range, fast speed = high volume delivery range (2) 200ul source plate volume per well for 96 Format and 75ul source plate volume per well for 384 Format

DMSO Pin Transfer Volume Range Charts

Uncoated Pins in 96 and 384 Format Microplates(1)
Pin TypePin Diameter(mm)Shape96 Format Low Range(nL)²96 Format High Range(nL)²384 Format Low Range(nL)³384 Format High Range(nL)³
FP90.229Solid41038
FP80.35Solid1326618
FP10.457Solid18431131
FP1S60.4576nL Slot24491534
FP1S100.45710nL Slot30542140
FP1S200.45720nL Slot37612746
FP1S300.45730nL Slot46683554
FP1S400.45740nL Slot57784563
FP1S500.45750nL Slot70905675
FP30.787Solid671392979
FP40.91Solid941973498
FP3S1000.787100nL Slot175241114163
FP3S2000.787200nL Slot280332203250
FP3S5000.787500nL Slot535559427464
FP4S10000.911000nL Slot9401011704800
FP4S20000.912000nL Slot1518160812771362
Footnotes: (1) Delivery volume range is determined by speed of withdrawal from source liquid: Z-Speed Range = 1.5-30 mm/sec, slow speed = low volume delivery range, fast speed = high volume delivery range (2) 200ul source plate volume per well (3) 75ul source plate volume per well
Hydrophobic-coated Pins in 96 and 384 Format Microplates(1)
Pin TypePin Diameter (mm)Shape96 Format Low Range(nL)²96 Format High Range(nL)²384 Format Low Range(nL)³384 Format High Range(nL)³
FP9H0.229Solid41038
FP8H0.35Solid924617
FP1H0.457Solid1539927
FP1S6H0.4576nL Slot23491432
FP1S10H0.45710nL Slot29532038
FP1S20H0.45720nL Slot35592643
FP1S30H0.45730nL Slot47693553
FP1S40H0.45740nL Slot54754158
FP1S50H0.45750nL Slot69905773
FP3H0.787Solid671342776
FP4H0.91Solid9518932102
FP3S100H0.787100nL Slot170227108164
FP3S200H0.787200nL Slot266320190239
FP3S500H0.787500nL Slot520542416456
FP4S1000H0.911000nL Slot9321000741805
FP4S2000H0.912000nL Slot1571163813511423
Footnotes: (1) Delivery volume range is determined by speed of withdrawal from source liquid: Z-Speed Range = 1.5-30 mm/sec, slow speed = low volume delivery range, fast speed = high volume delivery range (2) 200ul source plate volume per well (3) 75ul source plate volume per well
E-Clip, Uncoated Pins, for 96 and 384 Format Microplates(1)
Pin TypeDiameter (mm)Shape96 Format Low Range(nL)²96 Format High Range(nL)²384 Format Low Range(nL)³384 Format High Range(nL)³
FP1.58Solid Pointed147411168395
FPS.51.58500nL Slot442704631843
FPS1.581000nL Slot893113013431498
FPS21.582000nL Slot1911203826072767
FPS51.585000nL Slot3908429651805253
FP61.58Solid Flat323674154398
FP6S.51.58500nL Slot73410428551053
FP6S1.581000nL Slot1210150016381717
FP6S21.582000nL Slot2299238427873068
FP6S51.585000nL Slot4329465652375245
Footnotes:(1) Delivery volume range is determined by speed of withdrawal from source liquid: Z-Speed Range = 1.5-30 mm/sec, slow speed = low volume delivery range, fast speed = high volume delivery range (2) 200ul source plate volume per well (3) 75ul source plate volume per well